CLASS NO.
All rights strictly reserved. Reproduction or issue
to third parties in any form whatever is not permitted
without written authority, from the proprietors. .
NAME
2838 100 05424
TY
CHECK
SUPERS.
DATE
Property of
PHILIPS ELECTRONICS INDUSTRIES (TAIWAN) LTD.-C.E.
10
A4
0.9 BDL3245E/BDL4245E/BDL4645E
32”/42”/46” FHD LCD PUBLIC DISPLAY
2011-07-01 PHILIPS Page 26 of 38
MMD Con
idential
5. NON FUNCTIONAL REQUIREMENTS
5.1 Start up behavior
LED indication should respond in 1 seconds and picture shows up within 15 seconds (for
VIDEO, S-VIDEO, VGA and COMPONENT input), 15 seconds (for DVI input & Display Port), 15
seconds (for HDMI input) when the Display wakes from standby, or power on with DC switch or
cold start.
The first time AC On , power status is in Standby mode.
5.2 Default/Reset Control Values
The default/reset values (out-of-box setting) of the various controls are listed:
I/O:
Switch Default
Position
AC
Power
Switch
ON
Speaker
Switch
Internal
speaker
Startup, OSD Menu and PQ Values:
PICTURE DAC
V1.0_201101011B.x
5.3 External communication (RS232)
5.3.1 Its default settings as follow:
Baud Rate : 9600
Data bits: 8
Parity : None
Stop Bit : 1
Flow Control : None
5.3.2 Timing between each message should be a minimum of 500 ms
5.3.3 There should be a menu selection
( e.g. in the service menu) for the baud rate of 1200,
2400, 4800,9600, 19200,
57600, 115200
5.3.4 Philips SICP codes must be supported.
The SICP Commands
Document V1.6_201