Precautions in using ActiveSync
The message “Unknown Device” pops up after the
computer detects the USB device
This message may be displayed when you switch on
the terminal as it is mounted on the desktop charger.
If you dismount the terminal and then mount it back to
the charger, the ActiveSync program works properly.
The message “Connecting…” continues
Dismount the terminal from the desktop charger to
disconnect it from the computer.
On [ActiveSync], select File Set Connection
<Allow USB Connection>, and then, click [ok]. Connect
the terminal again.
If connection attempts continue to fail and the
message “Unknown Hardware Device” pos up
Abnormal status of the USB host in the computer may
result in connection fail. Remove the terminal from the
desktop charger, reboot the computer, and then, return
the terminal to the desktop charger.
The terminal does not work when you remove and
return the battery
To prevent this problem, you should press the [Power]
button or select [Exit] in the Start menu with the stylus
pen so that Windows Mobile (or Windows CE) should
“Exits System” before you remove the battery.
If you had to remove the battery due to an unavoidable
situation, and the terminal does not work properly,
press the button and the button at the same
time for hard-reset.
Note that hard-resetting deletes data from the memory.
Onlythedatainthelestoragearepreserved.