Configuration
Operating Manual PITreader, PITreader Firmware V1.5.x
1004806-EN-08
| 44
8.16 Reset to default settings
The PITreader base unit can be reset to its factory default settings via a short circuit at the
terminals TxD/RxD or in the web application. Different data is deleted depending on which
type of reset is selected.
Short circuit at the terminals TxD/RxD
The configuration data (including coding) and the block list are reset.
Follow the instructions below:
1. Before booting the device, create a short circuit at the terminals TxD and RxD.
The LED lights up yellow, the device does not boot.
2. Remove the short circuit.
The LED flashes yellow.
3. Recreate the short circuit within 10 seconds.
The LED lights up yellow and the device is reset to its factory default settings.
NOTICE
If the short circuit is not recreated within 10 seconds, the PITreader will start
up without the configuration data having been reset to the factory default
settings.
4. If the device has successfully been reset to the factory default settings, the LED lights
up green.
5. Remove the short circuit
The LED no longer lights up yellow / green and the boot process is continued.
INFORMATION
The description of how to reset the PITgatebox to the factory default set-
tings using PITreader can be found in the operating manual PIT gb RLLE y
ETH.
In the web application
In the web application you can choose which data to reset.
The following data can be reset to the factory default settings in the web application:
} Device configuration
} Diagnostic log
} Transponder block list
} Names of device groups
} Configuration of user data
Follow the instructions below:
Go to Maintenance -> Factory reset, click on Reset to factory default settings and se-
lect the data you wish to reset.