Key #0: Auto Arm
27
11. Key #0: Auto Arm
The Hunter-Pro Series & Captain 8 systems offer two ways to automatically arm the alarm system
to full and ‘Home 1’ modes: by day and hour, or after inactivity period.
11.1 By day
Master code the time for the
auto-arming in the following format hh:mm -OR- set a different day
You can set the alarm system to be automatically armed every day, at a defined hour. At this
preset time, a 45 sec. delay will start and the keypad will sound beeps. When the delay expires,
the normal Exit delay will start after which the system will be armed to full mode.
The Installer can program the system, so the auto-arming will arm the system to ‘Home 1’ mode.
11.2 Inactivity auto-arming
Master code
inactivity time in minutes (up to 250)
set the partitions that will be armed
/ to move to the left and right.
to select a partition (set to “+”), or deselect it (set to “-”).
to save.
The system can be automatically armed, after a period, in which no detector was activated, i.e.,
the premises is probably vacant and the alarm system was not armed.
This feature can help you ensure, that the premises will always be armed when it is no longer
occupied, e.g., during the night.
This feature can be set per partition, so some partitions can be armed automatically, while others
are not.
When “Inactivity to Arming” time is due, the partitions that are about to be armed (or are already
armed) are displayed as “X”, above the partition’s number. See the next example.
A sample auto-arming countdown screen: “45” is the auto-arming delay. “X” are partitions that
are either armed or about to be armed automatically: 2, 7-9.
The Installer can enable auto-arming with open zones and some existing faults.
Auto Arm By Day
ENTER/NEXT/END
Auto Arm By Day
Sunday 00:00
Auto Arm By Day
ENTER/NEXT/END
InactivityToArm
ENTER/NEXT/BACK
Inact. Per part
+++++++++++++++++
Auto Arming - 45
X XXX
10 11 12 13 14 1 5 161 2 3 4 5 6 7 8 9