PDP-5010FD
131
5678
56
7
8
C
D
F
A
B
E
Main flowchart (1)...Checking VOL OFFSET
[From Preparation]
Display RST MASK 12 (Light blue). / [MKS S62]
To the Recovery flowchart (1-1)
To the Recovery flowchart (1-2)
Set VOL OFFSET to the tentative setting value minus 64. / [VOF ∗∗∗]
No
Ye s
Set VOL OFFSET to the tentative setting value plus 48. / [VOF ∗∗∗]
Display RST MASK 10 (Pink). / [MKS S60]
No
Display RST MASK 02 (Red). / [MKS S52]
Display RST MASK 03 (Green). / [MKS S53]
Return VOL OFFSET to the tentative setting value. / [VOF ∗∗∗]
Determine the tentative setting value for VOL OFFSET as
the final value.
Ye s
To the Recovery flowchart (1-3)
No
Ye s
To the Recovery flowchart (1-4)
From the Recovery flowchart (1-2) and (1-4)
Ye s
No
[To the Main flowchart (2)]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)