PDP-5010FD
84
1234
1 234
C
D
F
A
B
E
6.1.6 FACTORY HIERARCHICAL TABLE
Large Item
Variable / Adjustment Range Remarks
Middle Item
Small Item
6.2.1 INFORMATION
6.2.1.1 VERSION (1)
6.2.1.2 VERSION (2)
CLEAR <=> NO <=> YES
MTB HOUR METER CLEAR NO <=> YES
6.2.1.3 VERSION (3)
6.2.1.4 MAIN NG
6.2.1.5 TEMPERATURE
6.2.1.6 HOUR METER
6.2.1.7 HDMI SIGNAL INFO 1
6.2.1.9 VDEC SIGNAL INFO 1
6.2.1.8 HDMI SIGNAL INFO 2
6.2.1.10 VDEC SIGNAL INFO 2
6.2.1.11 DTV TUNING STATUS 1
6.2.1.12 DTV TUNING STATUS 2
6.2.1.13 DTV TUNING STATUS 3
6.2.1.14 DTV TV-GUIDE BER
6.2.1.15 DEBUG INFO
6.2.2 PANEL FACTORY (+)
6.2.2.1 PANEL INFORMATION
6.2.2.2 PANEL WORKS
6.2.2.3 POWER DOWN
6.2.2.4 SHUT DOWN
6.2.2.5 PANEL-1 ADJ (+) VOL SUS <=> 000 to 255 Equivalent to VSU
(Setting value: Factory adjustment value)
VOL OFFSET <=> 000 to 255 Equivalent to VOF
(Setting value: Factory adjustment value)
VOL RST P <=> 000 to 255 Equivalent to VRP
(Setting value: Factory adjustment value)
VOL XPOFS1 <=> 000 to 255 Equivalent to VX1
(Setting value: Factory adjustment value)
VOL XPOFS2 <=> 000 to 255 Equivalent to VX2
(Setting value: Factory adjustment value)
VOL YNOFS1 <=> 000 to 255 Equivalent to VY1
(Setting value: Factory adjustment value)
VOL YNOFS3 <=> 000 to 255 Equivalent to VY3
(Setting value: Factory adjustment value)
VOL YNOFS4 <=> 000 to 255 Equivalent to VY4
(Setting value: Factory adjustment value)
RESET1ST_KSB <=> 112 to 144 Equivalent to R1K (Setting value: 128 fixed)
RESET2ND_KSB <=> 112 to 144 Equivalent to R2K (Setting value: 128 fixed)
YSTL_1SF_KSB <=> 112 to 144 Equivalent to Y1K (Setting value: 128 fixed)
YSTL_1SF_HZ <=> 112 to 144 Equivalent to Y1Z (Setting value: 128 fixed)
XSUS_1ST_B <=> 112 to 144 Equivalent to X1B (Setting value: 128 fixed)
YSUS_2ND_B <=> 112 to 144 Equivalent to Y2B (Setting value: 128 fixed)
XSUS_3RD_B <=> 112 to 144 Equivalent to X3B (Setting value: 128 fixed)
YSUS_B <=> 112 to 144 Equivalent to YSB (Setting value: 128 fixed)
XSUS_B <=> 112 to 144 Equivalent to XSB (Setting value: 128 fixed)
YSTL_KSB <=> 112 to 144 Equivalent to YTK (Setting value: 128 fixed)
YSTL_HZ <=> 112 to 144 Equivalent to YTZ (Setting value: 128 fixed)
YSTL_2SF_KSB <=> 112 to 144 Equivalent to Y2K (Setting value: 128 fixed)
YSTL_2SF_HZ <=> 112 to 144 Equivalent to Y2Z (Setting value: 128 fixed)
YSTL_FMR_KSB <=> 112 to 144 Equivalent to YNK (Setting value: 128 fixed)
YSTL_FMR_HZ <=> 112 to 144 Equivalent to YNZ (Setting value: 128 fixed)
SUS FREQ. <=> MODE 1 to MODE 8 Equivalent to SFR (Setting value: MODE1)
6.2.2.6 PANEL-2 ADJ (+) R-HIGH <=> 000 to 511 Equivalent to PRH
(Setting value: Factory adjustment value)
G-HIGH <=> 000 to 511 Equivalent to PGH
(Setting value: Factory adjustment value)
B-HIGH <=> 000 to 511 Equivalent to PBH
(Setting value: Factory adjustment value)
R-LOW <=> 000 to 999 Equivalent to PRL (Setting value: 512 fixed)
G-LOW <=> 000 to 999 Equivalent to PGL (Setting value: 512 fixed)
B-LOW <=> 000 to 999 Equivalent to PBL (Setting value: 512 fixed)
ABL <=> 000 to 255 Equivalent to ABL
(Setting value: Factory adjustment value)
6.2.2.7 PANEL FUNCTION (+) R-LEVEL <=> LV-0 to LV-7 Equivalent to RRL (Setting value: Lv-1)
G-LEVEL <=> LV-0 to LV-7 Equivalent to RGL (Setting value: Lv-1)
B-LEVEL <=> LV-0 to LV-7 Equivalent to RBL (Setting value: Lv-0)
ADDRESS L1 <=> PH0 to PH9 Equivalent to AP0S*- (Setting value: PH1)
ADDRESS L2 <=> PH0 to PH9 Equivalent to AP0S-* (Setting value: PH0)
ADDRESS L3 <=> PH0 to PH9 Equivalent to AP1S*- (Setting value: PH2)
ADDRESS L4 <=> PH0 to PH9 Equivalent to AP1S-* (Setting value: PH1)
ADDRESS U1 <=> PH0 to PH9 Equivalent to AP2S*- (Setting value: PH1)
ADDRESS U2 <=> PH0 to PH9 Equivalent to AP2S-* (Setting value: PH0)
ADDRESS U3 <=> PH0 to PH9 Equivalent to AP3S*- (Setting value: PH2)
ADDRESS U4 <=> PH0 to PH9 Equivalent to AP3S-* (Setting value: PH1)
STK MODE <=> OFF <=> MODE1 to MODE8 <=> SKM S00 to S07