PDP-5010FD
156
1234
1 234
C
D
F
A
B
E
9.3.2 QS2 (PANEL OPERATION DATA)
Data Arrangement
Data
Length
Output Example
ECO 3 byte QS2 (fixed)
1 Power supply status 1 byte 0
2 Adjustment flag of the main unit 1 byte 0
3 Adjustment-data backup flag 1 byte 0
4 "1st PD" data 1 byte 0
5 "2nd PD" data 1 byte 0
6 Reserved 3 byte
∗∗
7 Temperature data (TEMP 1) 3 byte 063
8 SD main data 1 byte 0
9 SD sub data 1 byte 0
10 Operation status induced by SD 1 byte 0
11 Reserved 3 byte 0
12 HOUR METER 8 byte 00000437
13 MASK indication 1 byte 0
14 Still picture detection 1 byte 7C
15 SCAN protection detection 1 byte
16 Panel crack detection 1 byte
17 Address emergency detection 1 byte
18
19
Reserved 4 byte
CS 2 byte
1:
Power supply status
0
Entering Passive
mode failed during
standby
P
During power ON
1
Entering Passive
mode succeeded
during standby
2: Adjustment flag of
the main unit
0
Adjustment completed
1
Adjustment not
completed
3: Adjustment-data
backup flag
0 With backup data
1 No backup data
4, 5: PD data
0 No PD data
1 Not used
2POWER
3 SCAN
4 SCN-5V
5Y-DRV
6 Y-DCDC
7 Y-SUS
8 ADRS
9 X-DRV
A X-DCDC
9-1: SD-Sub (SQ_LSI)
0 No SD-Sub data
1 Communication error
2 Drive stop
3 BUSY
4 Version mismatching (H/S)
B X-SUS
C DIG-DCDC
D Not used
E Not used
F UNKNOWN
8: SD main data
0 No SD
1 SQ_LSI communication error
2 MDU-IIC communication error
3 Abnormally in RST2
4 TEMP
10: Operation status
induced by SD
0 Normal
1 Relay-off completed
2
During warning
indication
13: MASK indication
0 MASK-OFF
1 MASK-ON
14 to 17: Detection of Each Protection function
0 Normal operation
1 At detection of protection operation
Command
Format
Effective Operation
Modes
Function Remarks
[QS2] All operations
To acquire data on operations of the panel
Return data: 3 (ECO) + 34 (DATA) + 2 (CS) = 39 Byte
The command QS2 is for acquiring data on the panel's operational information.
9-2: SD-Sub (MDU-IIC)
0 No SD-Sub data
1 EEPROM
2 BACKUP
3DAC1
4DAC2
9-3: SD-Sub (TEMP)
0 No SD-Sub data
1 TEMP1 high temperature
2 TEMP1 low temperature
5 Version mismatching (M/S)

Table of Contents