6. SERVICE FACTORY MODE
6.1 OUTLINE OF THE SERVICE FACTORY MODE
6.1.1 SERVICE FACTORY MODE TRANSITION CHART
6.1.2 HOW TO ENTER/EXIT SERVICE FACTORY MODE
Operations during Service Factory mode are described here.
POWER
[POF]
FACT
[FAY]
FACT
HOME MENU
[FAN]
RS-232C Factory mode
OPTION
INITIALIZE
[ (MUTING)]
Effective 232C
Effective IR in Factory mode
command in Factory mode
Standby mode Power supply ON mode
PANEL FACTORY
The function is changed.
The signal mode is changed.
INFORMATION
(MTB INFORMATION)
How to enter Service Factory Mode
By using a PDP service remote control)
• PDP service remote control : Press [FACTORY] key.
By issuing RS-232C commands )
• During normal Standby mode : Issue [PON] then [FAY].
• During normal operation mode : Issue [FAY].
How to exit Service Factory Mode
By using a PDP service remote control)
• PDP service remote control : press [FACTORY] key.
• Supplied remote control unit : press [HOME MENU] key.
By issuing RS-232C commands)
• Issue [FAN].
How to enter Service Factory Mode by Using the
supplied Remote Control Unit
• Same as previous model. Please refer to the technical document
(Service Know-how).