5678
56
7
8
C
D
F
A
B
E
9.3.8 QSD (SD LOGS)
Data Arrangement
Data
Length
Output Example
ECO 3 byte QSD (fixed)
1 Latest SD data 1 byte 1
2 Latest SD subcategory data 1 byte 0
3 Data from the hour meter for the latest SD 8 byte 00752013
4 Second latest SD data 1 byte 5
5 Second latest SD subcategory data 1 byte 0
6 Data from the hour meter for the second latest SD 8 byte 00456378
7 Third latest SD data 1 byte 2
8 Third latest SD subcategory data 1 byte 3
9 Data from the hour meter for the third latest SD 8 byte 00347845
10 Fourth latest SD data 1 byte 2
11 Fourth latest SD subcategory data 1 byte 4
12 Data from the hour meter for the fourth latest SD 8 byte 00175635
13 Fifth latest SD data 1 byte 1
14 Fifth latest SD subcategory data 1 byte 0
15 Data from the hour meter for the fifth latest SD 8 byte 00083450
16 Sixth latest SD data 1 byte 2
17 Sixth latest SD subcategory data 1 byte 2
18 Data from the hour meter for the sixth latest SD 8 byte 00045662
19 Seventh latest SD data 1 byte 0
20 Seventh latest SD subcategory data 1 byte 0
21 Data from the hour meter for the seventh latest SD 8 byte 00000000
22 Eighth latest SD data 1 byte 0
23 Eighth latest SD subcategory data 1 byte 0
24
25
Data from the hour meter for the eighth latest SD 8 byte 00000000
CS 2 Byte 7D
Command
Format
Effective Operation
Modes
Function Remarks
[QSD] All operations
To acquire data on the shutdown logs
Return data: 3 (ECO) + 80 (DATA) + 2 (CS) = 85 Byte
The command QSD is for acquiring the data from the 8 latest shutdown (SD) logs.
" SD data (Main)
0 No SD (Main)
1 SQ_LSI communication error
2 MDU-IIC communication error
3 Abnormally in RST2
4 TEMP
" SD subcategory (SQ_LSI)
0 No SD-Sub data
1 Communication error
2 Drive stop
4 Version mismatching (H/S)
3 BUSY
" SD subcategory (Main: MDU-IIC)
0 No SD-Sub data
1 Main-EEPROM
2 Backup-EEPROM
3DAC1
4DAC2
" SD subcategory (Main: TEMP)
0 No SD-Sub data
1 TEMP1 (high temperature)
2 TEMP1 (low temperature)
5 Version mismatching (M/S)