PDP-5010FD
136
1234
1 234
C
D
F
A
B
E
Recovery flowchart (2-1)...Changing the VOL YNOFS3/4/1 setting voltage
[From the Main flowchart (2)]
Set VOL YNOFS1 to the tentative setting value. / [VY1 ***]
Set VOL YNOFS3 to the current setting value +4. / [VY3 ***]
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Ye s
To the Recovery flowchart (2-2)
From the Recovery flowchart (2-2)
Ye s
Current VOL YNOFS3 setting value > 137?
No
Is there erroneous discharge (abnormal dead cell)?
No
Is there erroneous discharge (abnormal dead cell)?
Set VOL YNOFS4 to the current setting value +4. / [VY4 ***]
Display RST MASK 22 (Cyan 3SF). / [MKS S72]
Set VOL YNOFS3 to the current setting value +47. / [VY3 ***]
Set VOL YNOFS4 to the current setting value +47. / [VY4 ***]
RST MASK 16 (Green 1023+)
Display RST MASK 15 (Red 1023+). / [MKS S65]
No
Ye s
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)