EasyManua.ls Logo

Pioneer PDP-5010FD - Page 138

Pioneer PDP-5010FD
187 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDP-5010FD
138
1234
1 234
C
D
F
A
B
E
Recovery flowchart (2-3)...Changing the VOL YNOFS3/4/1 setting voltage
[From the Main flowchart (2)]
Set VOL YNOFS1 to the tentative setting value. / [VY1 ***]
Set VOL YNOFS3 to the current setting value minus 4. / [VY3 ***]
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Ye s
Current VOL YNOFS3 setting value < 094?
No
Is there erroneous discharge (abnormal lit cell)?
Set VOL YNOFS4 to the current setting value minus 4. / [VY4 ***]
Display RST MASK 15 (Red 1023+). / [MKS S65]
Set VOL YNOFS3 to the current setting value plus 23. / [VY3 ***]
Set VOL YNOFS4 to the current setting value plus 23. / [VY4 ***]
Set VOL YNOFS3 to the current setting value minus 47. / [VY3 ***]
Set VOL YNOFS4 to the current setting value minus 47. / [VY4 ***]
RST MASK 22 (Cyan 3SF)
Display RST MASK 16 (Green 1023+). / [MKS S66]
No
Ye s
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Determine the current setting value for VOL YNOFS3 as the final value.
Determine the current setting value for VOL YNOFS4 as the final value.
[To the Main flowchart (2)]
Set VOL YNOFS1 to the final setting value of VOL YNOFS3 minus 31.
/ [VY1 ***]
Determine the current VOL YNOFS1 setting value as the final value.
VOL YNOFS3 final setting value
Note:
Make a note of this VOL YNOFS3 value.

Table of Contents