Fan and temperature sensor
Circuit configuration
MAIN Assy
PANEL SENSOR
Assy
FHD FAN
CONNECT Assy
TANSHI Assy
DIGITAL Assy
IF_UCOM
V+3_3V_UCOM
PULL_U
FAN
1
FAN
FAN
FAN
V+3_3V_UCOM
TEMP1
SENSOR
MAIN_UCOM
DAC
MODULE_
UCOM
PULL_D
Specifications for port monitoring
Port Name SD/PD Indication Active
FAN_NG1 FAN1
Shutdown occurs when 
the signal is "H."
1 S ∗ 3 times
TEMP2 High temperature at 
MTB
Shutdown occurs if any 
values equal to or 
greater than minimum to 
require a shutdown are 
detected.
1 S ∗ 3 times
Monitoring conditions
RST4 = H and FAN_ON1 = H 
(Monitoring starts 3 sec after the 
above conditions are established.)
Operation
If FAN_NG1 (for details on detection logic, see "File of 
fan-control specifications") is detected (established) under the 
monitoring conditions, a shutdown process starts. A specific 
LED flash pattern (blue LED, 10 times) starts. 
The next PON operation is valid, and the flag is cleared upon 
the next power-on.
FAN_NG2 FAN
Shutdown occurs when 
the signal is "H."
1 S ∗ 3 times
RST4 = H and FAN_ON2 = H 
(Monitoring starts 3 sec after the 
above conditions are established.)
If FAN_NG2 (for details on detection logic, see "File of 
fan-control specifications") is detected (established) under the 
monitoring conditions, a shutdown process starts. A specific 
LED flash pattern (blue LED, 10 times) starts. 
The next PON operation is valid, and the flag is cleared upon 
the next power-on.
RST4 = H
 (Monitoring starts 1 sec after the 
above conditions are established.)
If any values equal to or greater than minimum to 
require a shutdown are detected (established) under 
the monitoring conditions, a warning indication will be 
displayed for 30 sec, after which a shutdown process 
starts. A specific LED flash pattern (blue LED, 11 times) 
starts. 
The next PON operation is valid, and the flag is cleared 
upon the next power-on.
TMP_NG
High temperature in 
the drive circuits
Low temperature in 
the drive circuits
Shutdown occurs if any 
values equal to or 
greater than minimum to 
require a shutdown are 
detected.
200 mS ∗ 5 times 
(average)
Digital video RST2 = H
If any values equal to or greater than minimum to 
require a shutdown is detected (established) under the 
monitoring conditions, those changes in status will be 
transmitted to the main microcomputer via the UART. 
Upon receiving the data, a warning indication will be 
displayed for 30 sec, after which a shutdown process 
starts. The main microcomputer orders a specific LED 
flash pattern (blue LED, 4 times). 
The next PON operation is valid, and the flag is cleared 
upon the next power-on.
If any values equal to or greater than minimum to 
require a shutdown is detected (established) under the 
monitoring conditions, those changes in status will be 
transmitted to the main microcomputer via the UART. 
Upon receiving the data, the main microcomputer 
orders a specific LED flash pattern (blue LED, 4 times). 
The next PON operation is valid, and the flag is cleared 
upon the next power-on.