OPERATION & MAINTENANCE MANUAL TMS2000/3000
TMS Operations and Maintenance Manual.docx February 12, 2018
PAGE 20
2.4.1.4 THEFTS LOG
Log
Inventory Inventory
deLivery Deliveries
SALES Bulk Sales
tHEFtS Thefts
Orders Product Reordering Report
Water Bottom Water Removal
tank Leak In-Tank Leak Test – Detailed Results
Leak Hist In-Tank Leak Test – History
LIne Leak LS300 Line Leak Test
ALArMS Alarms
Events Events
return Return
tHefts Thefts: An optional transaction log that represents the withdrawal or theft of the primary liquid from the
tank during hours when the facility is not in operation. Theft monitoring may be enabled for individual
tanks in the Tank submenu of the Configuration menu. The hours of operation are defined in the Theft
submenu of the Configuration menu. All transactions depend on the TMS Clock functionality to be
recognized.
Record Storage Capacity: 6. 1 Tank Channel per record.
TMS Configuration Prerequisites:
Configuration menu, Tank submenu, Theft Enable: Enables Theft monitoring for specified Tank Channel.
Configuration menu, Theft submenu: Defines Hours of Operation for facility
Configuration menu, Probe submenu, Motion Height Band: Defines Transaction recognition
Configuration menu, Probe submenu, Minimum Logged Volume: Defines Transaction Logging
Group ID: Record Number.
Record Identification Data:
mm-dd Date (Month-Day): Date the scheduled Inventory Snapshot was recorded.
Note: an empty record will show 00-00.
HH'mm Time (Hour’ Minute): Time the scheduled Inventory Snapshot was recorded.
Note: time stored in 24 hr. format
Examples: 12’00 = 12 Noon 23’59 = 11:59 PM 00’00 = Midnight
tank Name Tank Name: As Assigned in the Configuration menu, Tank submenu.
Prod type Product Type: As Assigned in the Configuration menu, Tank submenu.
tank id Tank ID Number: As Assigned in the Configuration menu, Tank submenu.
Captured Data:
Begin Ht Beginning Height: Total Liquid Level at the Beginning of the Theft.
End Ht Ending Height: Total Liquid Level at the End of the Theft.
Beg temp Beginning Temperature: Average Product Temperature at the Beginning of the Theft.
End temp Ending Temperature: Average Product Temperature at the End of the Theft.
Gr Begin Gross Beginning Volume: Total Gross Volume at the Beginning of the Theft.
Gr End Gross Ending Volume: Total Gross Volume at the End of the Theft.
Gr diFF Gross Difference: Total Gross Volume Stolen from tank. Calculated as:
(Gross Beginning Volume) – (Gross Ending Volume).
Net begin Net Beginning Volume: Total Net Volume at the Beginning of the Theft.
Net End Net Ending Volume: Total Net Volume at the End of the Theft.
Net diFF Net Difference: Total Net Volume Stolen from tank. Calculated as:
(Net Beginning Volume) – (Net Ending Volume).
Exit Thefts submenu:
Return Return: Press EDIT (TEST) to exit Thefts submenu.
Note: Press STEP (MODE) to return to top of Thefts submenu showing mm-dd (Month-Day)