2.2 OVERVIEW OF OPERATING MODES/SYSTEM FUNCTION TREE
TMS front panel operation is defined by three user-selectable modes, View, Test, and Access, all selected using the
MODE and TEST pushbuttons. See Figure 2.2, System Function Tree below.
Figure 2.2: System Function Tree
VIEW: View mode is the most frequently used and the default mode of operation for the console. The View mode
displays current tank data, which includes product gross and net (temperature compensated) volumes, percent of
capacity, ullage, product and bottom water levels, product temperature, and product name. In addition, alarm and
error conditions are annunciated in the View mode. If the system includes the optional impact printer, on demand
printed inventory reports including complete tank/sensor alarm statuses can be generated. See Section 2.3 for
complete details.
ACCESS: Access mode provides access to all of the menus shown in Figure 2.2. In this mode the user can review
and print report logs; review, edit and print system configuration data; enable or schedule in-tank leak tests; perform
initialization functions; read or set the system clock. See Section 2.4 for complete details.
TEST: Test mode allows visual verification of display operation, audible verification of the audible annunciator, and
self-verification of critical system hardware.
INVENTORY
DELIVERY
bulk SALES
THEFTS
produc t ORDERS
WATER remo val
in- TANK LEAK tes t resu l ts
in- t ank LEAK tes t HISTo ry
LINE LEAK tes t resu l ts
ALARMS
EVENTS
VIEW
in- t ank LEAK
TEST scheduling
CLOCK
INITialize D ATA
LOG
CONFIGur ation
ACCESS
SYSTEM TEST
HEADER
TANK
PROBE
RELaY TANK
RELaY CC
RELaY SENSor
RELaY Line Leak Pane l
RELaY SITE
RELaY MODE
CC INPUT
SENSoR INPu t
INVENTORY
THEFT
MODEM
DIAL OUT
in- TANK LEAK tes t
ANALOG OUTputs

Table of Contents