EasyManua.ls Logo

Pneumercator TMS2000 - Dsp Mode; Baud Rate; Serial Format

Pneumercator TMS2000
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION & MAINTENANCE MANUAL TMS2000/3000
TMS Operations and Maintenance Manual.docx February 12, 2018
PAGE 35
Dsp Mode Default Display Mode: The TMS will return to the Default Display Mode when no buttons are
pressed for approximately four minutes.
Entry Type: select list
Range Limits: Gr Vol: Gross Volume in Gallons/Liters
Level: Level in Inches/Millimeters
PctVol: Product Gross Volume as a percentage of Total Tank Capacity
NetVol: Net (Temperature-Compensated) Volume in Gallons/Liters
Default/Initialized value: gr VoL
Baud rate Baud Rate (Port A): This entry allows the user to select the baud rate for the Primary RS-232
serial communications port in the TMS.
Entry Type: select list
Range Limits: 1.2K, 2.4K, 4.8K, 9.6K, 38.4K (K = 1,000. i.e 9.6K =9600)
Default/Initialized value: 9.6K
SeriaLfmt Serial Format (Port A): This entry allows the user to select the serial format for the Primary
RS-232 serial communications port in the TMS. Additional settings are available to support the
external LS300 Line Leak Panel.
Entry Type: select list
Range Limits: n,8,1: No Parity, 8 Data Bits, 1 Stop Bit
e,7,1: Even Parity, 7 Data Bits, 1 Stop Bit
o,7,1: Odd Parity, 7 Data Bits, 1 Stop Bit
LS3-4: LS300 4-channel
LS3-8: LS300 8-channel
E Prn: External Printer (Future Use)
Default/Initialized value: n-8-1
Baud rate Baud Rate (Port B): This entry allows the user to select the baud rate for the Auxiliary RS-232
serial communications port in the TMS.
Entry Type: select list
Range Limits: 1.2K, 2.4K, 4.8K, 9.6K, 38.4K (K = 1,000. i.e 9.6K =9600)
Default/Initialized value: 9.6K
SeriaLfmt Serial Format (Port B): This entry allows the user to select the serial format for the Auxiliary
RS-232 serial communications port in the TMS. Additional settings are available to support the
external LS300 Line Leak Panel.
Entry Type: select list
Range Limits: n,8,1: No Parity, 8 Data Bits, 1 Stop Bit
e,7,1: Even Parity, 7 Data Bits, 1 Stop Bit
o,7,1: Odd Parity, 7 Data Bits, 1 Stop Bit
LS3-4: LS300 4-channel
LS3-8: LS300 8-channel
E Prn: External Printer (Future Use)
Default/Initialized value: n-8-1
tank qty Tank Quantity: OBSOLETE. Previously used to define the number of Tank Channels being
used.
Entry Type: 2-digit numeric
Range Limits: 0-19
Default/Initialized value: 0
SP Units Product SetPoint Units: (3 Product SetPoint Firmware Only: Vxx99xx or Vxx00xx). Establishes
the units used to define the Product SetPoints. If this setting is changed, all Product SetPoint
thresholds need to be reviewed and properly set for the application.
Entry Type: select list
Range Limits: PVol: Percent of Total Tank Capacity
GrVol: Gross Volume in Gallons/Liters
Level: Level in Inches/Millimeters
Default/Initialized value: PVoL