2.4.1.9 LS300 LINE LEAK TEST LOG
Log
Inventory Inventory
deLivery Deliveries
SALES Bulk Sales
tHEFtS Thefts
Orders Product Reordering Report
Water Bottom Water Removal
tank Leak In-Tank Leak Test – Detailed Results
Leak Hist In-Tank Leak Test – History
LIne Leak LS300 Line Leak Test
ALArMS Alarms
Events Events
return Return
LIne Leak LS300 Line Leak Test: Contains the Date and Time of the latest Pass and Fail for each of the three
supported Line Leak Rates. The TMS does NOT perform the Line Leak Test. An external LS300 Line
Leak Console connects to the TMS via RS-232 in support of this Log.
Record Storage Capacity: 8
TMS Configuration Prerequisites:
Configuration menu, Header submenu, Serial Format settings: Selects RS-232 port for LS300 support.
Group ID: LS300 Line Leak Channel Number.
Record Identification Data:
Prod Name Product Name: Tank Name assigned by user to the associated Tank Channel.
Captured Data:
Pass 3gPH Pass 3 GPH: Date and Time of the latest passing 3 GPH [12 LPH] test.
FaiL 3gPH Fail 3 GPH: Date and Time of the latest failing 3 GPH [12 LPH] test.
Pass .2gPH Pass 0.2 GPH: Date and Time of the latest passing 0.2 GPH [0.8 LPH] test.
FaiL .2gPH Fail 0.2 GPH: Date and Time of the latest failing 0.2 GPH [0.8 LPH] test.
Pass .1gPH Pass 0.1 GPH: Date and Time of the latest passing 0.1 GPH [0.4 LPH] test.
FaiL .1gPH Fail 0.1 GPH: Date and Time of the latest failing 0.1 GPH [0.4 LPH] test.
Exit Line Leak submenu:
Return Return: Press EDIT (TEST) to exit Line Leak submenu.
Note: Press STEP (MODE) to return to top of Line Leak submenu showing mm-dd