Appendix V: Instruction of Profitbus –DP
communication card
V-1.Outline
9KDP1 meet the international standard PROFIBUS fieldbus, powtran technology 9K series
inverter use it together to achieve the drive to become a part of fieldbus complete control of real
fieldbus. Before using this product, please carefully read this manual
V-2 Terminal function
V-2-1 DIP switch description
DP Card and the
drive baud rate
selection
Profibus-DP
Communication
from the station
address
6 Binary Consisting of 64-bit binary address, more than 64 outside
the address can be set only by function code. The following lists some
slave address and switch settings
Address switch settings
0 00 0000
7 00 0111
20 01 0100
Table V-1:Switch Functions
V-2-2 Terminal Function
1) External communication terminal J4-6PIN
Table V-2:External communication terminal function
2) Upper machine communication interface SW1-8PIN
PC 232 communication Sending
side
PC 232 communication receiving
side
Table V-3:PC communication terminal function
V-2-3 LED Light function
If DP card and drive interfaces connected, the inverter after
power LED should be in the steady state
DP Card and inverter connected to the normal state of the