Chapter 5 Function parameter
37
Keyboard Encoder set value
Keyboard Encoder X1
corresponding value Y1
Keyboard Encoder X2
corresponding valueY2
Bits:
0: Power down protection
1: Power down zero clear
Ten bits:
0: Stop keep
1: Stop order zero clear
2: Stop over zero clear
Hundred bits: reserve
Thousand bits: reserve
5-1-4.F2 Group - Output terminals group
SPB terminal output mode selection
Switching quantity output function
selection
Relay 1 output function selection
(TA1.TB1.TC1)
SPA output function selection
(collector open circuit output
terminals)
Relay 2 output function selection
(TA2.TB2.TC2)
Above 5 function code is used to select five digital output function. Multifunctional output
terminal functions are as follows:
Inverter is in running state, the output frequency (can be
zero), the output ON signal.
Fault output (fault
down )
When the drive fails and downtime, the output ON signal.
Frequency level
detection FDT1 output
Please refer to the function code F7.23, F7.24's
instructions.
Please refer to the description of function code F7.25.
Zero-speed running (no
output when shutdown)
Inverter operation and the output frequency is 0, output
ON signal. When the drive is shut down, the signal is