Ether232Plus User Guide 4 Configuring the Serial Port Settings
02-CML000057 Precidia Technologies Inc. 31
2 Choose
Remote IP
from the Serial Port Settings sub-menu.
You are prompted to enter the IP address of the remote system.
3 Type the remote IP address and press
Enter
.
4.8 Remote Port
Remote Port is the port address on the remote device to which the Ether232Plus sends
incoming data. Remote Port must be set in tcp(tunnel), tcp-client, and udp modes.
To enter or change the Remote Port:
1 Choose
Serial Port
from the Device Settings menu.
2 Choose
Remote Port
from the Serial Port Settings sub-menu.
You are prompted to enter the port number on the remote system.
3 Type the remote port number at the prompt and press
Enter
.
4.9 Fallback IP
Fallback IP is the IP address of the machine the unit connects to if the Remote IP
address (primary) is not responding, not accepting connections, or not sending data.
The unit makes one attempt to connect to the Remote IP. If that attempt fails, it
attempts to connect to the Fallback IP, alternating until a connection is made. After
connecting to the Fallback IP address, the unit tries the Remote IP on the next attempt.
If data is received from either host, the next connection attempt is to the Remote IP
address.
Fallback can also be disabled, or enabled to accept incoming connections from any
host. Table 4.5 describes Fallback IP settings.