Ether232Plus User Guide 7 Accessing System Information
02-CML000057 Precidia Technologies Inc. 63
Understanding the System Log
Table 7.3 describes System Log messages you may see when performing a System
Log dump, and Table 7.4 lists possible error messages and what to do about them.
Table 7.3: System Log Messages
Message Description
=====Ether232Plus Started=====
The unit has been started by: plug-
ging in the power adapter, saving a
new configuration, timing out during
local configuration, exiting configu-
ration without saving, or choosing
Reset Unit from the System Settings
menu. No timestamp presented. This
message indicates the unit was
started in normal mode. Timestamp
will start counting from zero (0)
after this message.
=====Ether232Plus Log Deleted=====
The Ether232Plus had its log
deleted. If present, this message will
always be the first entry in the log.
CONSOLE: login accepted
The unit went into console configu-
ration mode, a password prompt was
given, and the correct password was
entered.
CONSOLE: login rejected (timeout)
The unit went into console configu-
ration mode, a password prompt was
given, but no response was input
within the 30 second timeout period.
Unit resets.
CONSOLE: login rejected (invalid pass-
word)
The unit went into console configu-
ration mode, a password prompt was
given, but the password entered did
not match the configured Console
Password. Unit resets.
TELNET: login from xxx.xxx.xxx.xxx
rejected (configuration already running)
The unit went into telnet configura-
tion mode, a password prompt was
given, and the correct password was
entered, but configuration was
already running (probably locally
through the COM port).