Ether232Plus User Guide 7 Accessing System Information
02-CML000057 Precidia Technologies Inc. 59
3 Choose
Display System Status
from the System Settings sub-menu.
The System Status page appears, as shown below.
Understanding the System Status Page
The System Status page has three sections:
• System Uptime
• Port #1
• Network Routing
System Uptime
This section reveals how long the system has been operating, the loading on the
Precidia device's CPU, and the firmware version in the Precidia unit. Table 7.1
describes each parameter.
Ether232Plus Status:
Current time is 2004-03-12 20:26:10
System Uptime
Up 0 days, 0:07:57
Load Average: 5sec=19% 30sec=7% 5min=4% 30min=0%
Firmware Revision: 4.04.00 (2004-03-05)
Port #1 [serial] (transparent/tcp-server, idle)
Received Transmitted
Bytes: 0 Bytes: 0
Packets: 0 Packets: 0
Avg-BpP: 0 Avg-BpP: 0
Network Routing
Local Network Subnet Mask Gateway Iface Pkts-I
n Pkts-Out Pkts-Err
100.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 ipsec 0
0 0
0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 ipsec 0
0 0
192.168.1.30 192.168.1.0 255.255.255.0 eth 142
66 0
127.0.0.1 127.0.0.0 255.0.0.0 lo 0
0 0
Please hit <return>:
Example of the System Status Page
Table 7.1: System Uptime on the System Status Page
Parameter Description
Time
The length of time the system has been operating since the last
reset in days, hours:minutes:seconds. Note that the time is not
accurate and may drift slightly.
Load Average
The loading (activity) of the Ether232Plus CPU.
Firmware
Revision
The software version currently installed in the Ether232Plus with
the date of the software build in parentheses.