Disabling the ASL Maintenance Reminder
When set to ON, the ASL maintenance reminder - pulsing blue light state is triggered ON
when the maintenance counter counts down to zero miles (or zero hours). When set to OFF,
the ASL Maintenance Remindercounter is ignored and the ASL state is not changed to
pulsing blue.
l The "OFF" setting effectively disables the ASL "blue pulsing" state without affecting the
yellow or pulsing yellow fault states.
l When set to OFF, the Maintenance Reminder counter continues counting down the
miles (or hours) remaining which can be viewed in the service access menu, see "View-
ing the current ASL state" below.
l Error code events will still affect the ASL state condition even when the Maintenance
Reminder is set to OFF.
P10, P30, P30i and P31 consoles:
Access Club Settings (5651565) > MAINT CONFIG > select ON or OFF.
P62, P80, and P82 consoles:
Access Club Settings (5651565) > Maintenance menu > Maintenance Reminder > select
ON or OFF.
Viewing the current ASL state
The current ASL state (solid blue, pulsing blue, solid yellow; or pulsing yellow) can be viewed
using the service menu ACTIVE STATUS LIGHT parameter.
P10, P30, P30i and P31 consoles:
Access Hardware Validation (51765761) > ACTIVE STATUS LIGHT > current ASL state.
P62, P80, and P82 consoles:
Access Club Settings (5651565) > Maintenance menu > ACTIVE STATUS LIGHT > cur-
rent ASL state.
Viewing the ASL maintenance counter remaining miles (or hours)
P10, P30, P30i and P31 consoles:
Access Information Display (65) > MAINT COUNTER: remaining miles (or hours) to zero.
P62, P80, and P82 consoles:
Access Service Software (51765761) > Maintenance menu > Next Maintenance Due
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 178
7 Troubleshooting
Active Status Light (ASL)