562200-000, Issue 1.2, December 2015
21 of 62
7.6 Overload / Hydraulic Limitation Control Override
7.6.1 Soft Override
After three seconds a soft override button may replace the Lifting Mode but-
ton. If soft override is utilised, the machine hydraulics will be re-enabled. How-
ever, the external alarm will stay active, the red LED will flash, and the beacon
(if fitted) will switch off. Once the alarm condition has been corrected the RCC
will automatically clear the override request and revert to normal operation.
7.6.2 Master Override key Switch
The system can optionally be fitted with a key operated
Master override switch. Turning the switch to the override
position will allow normal operation of any of the hydraulic
services regardless of safety status. When the unit is in override the external
alarms will stay active, and the beacon (if fitted) will indicate that the machine
is overridden, the red LED will flash and an In Override message will appear
on the display. See section 4.1 for further details.
Soft override