EasyManuals Logo

ProMinent gamma/ X User Manual

ProMinent gamma/ X
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
0
1
2
3
4
5
6
7
8
9
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
0
2
4
6
8
10
12
14
16
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
0
5
10
15
20
25
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
C [l/h] f [%]
s [%]
GMXa 1009
C [l/h] f [%]
s [%]
GMXa 0715
C [l/h] f [%]
s [%]
GMXa 0220
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
80
70
100
50
40
30
20
10
60
C [l/h] f [%]
s [%]
GMXa 2504
200 1/min
180 1/min
160 1/min
140 1/min
120 1/min
100 1/min
80 1/min
60 1/min
40 1/min
20 1/min
Fig. 67: Capacity C at medium back pressure depending on the stroke length s for different stroke rates f
Diagrams for Setting the Capacity
126

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%