4. To run through the figures again, if necessary ( possibly because of
an incorrect figure), when you get to the last figure press
[Priming]
again - see Fig. above, point c).
ð
Now you can start from the beginning again.
Press the
[Clickwheel]
1x.
ð
The software saves the entry.
10.2 Checking adjustable variables
Before you adjust the pump, you can check the actual settings of the
adjustable variables:
Simply turn the
[Clickwheel]
if the pump is showing a continuous
display.
ð
Each time the
[Clickwheel]
engages when you turn it, you will
see a different continuous display.
The number of continuous displays depends on the identity
code, the selected operating mode and the connected addi‐
tional devices, see overview "Continuous displays" in the
appendix.
The lowest line of a continuous display shows different information (which
cannot be adjusted in the secondary display) - see overview "Continuous
displays and secondary displays" in the appendix.
You can access secondary displays via any continuous display as follows:
1. Press the
[Clickwheel]
for 3 seconds.
ð
A frame appears around the secondary display.
2. Providing there is a frame, you will see a different secondary display
each time the
[Clickwheel]
engages when turned.
When you reach the secondary display you wish, leave the
[Clickwheel]
and wait briefly.
10.3 Changing to set up mode
In a continuous display, if you press
‘Menu’
, the pump changes to set-
up mode - in the
‘Menu’
. For more information refer to the following
chapter entitled "Set-up / menu".
If under
‘Access protect.’
only the
‘Menu’
or
‘All’
has been set (top left
lock symbol), then after pressing the
[Clickwheel]
, first enter the
‘Password’
.
Confirming adjustable variables
Continuous displays
Secondary displays
Basic Set-up Principles
44

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%