3. To start calibration, press the
[Clickwheel]
.
ð
The
‘Calibrate ...’
menu item appears, the pump starts to pump
and indicates the number of strokes.
4. After a reasonable number of strokes (a minimum of 200), use the
[Clickwheel]
to stop the pump.
ð
The
‘Calibration ended’
menu point appears. It demands the
calibration volume to be entered.
5. Determine the required metering volume (difference between initial
volume - remaining volume in the measuring cylinder).
6. Use the
[Clickwheel]
to enter this volume in the
‘Calibration ended’
menu items and close.
ð
The pumps switches to the
‘Calibration result’
menu item - the
pump is calibrated.
7. Press the
[Clickwheel]
.
ð
The pump returns to the
‘Menu / Information
è
Settings’
menu.
11.2.6 System
‘Menu / Information
è
Settings
è
System
è
...’
The
‘System’
menu splits into the following sub-menus:
1 -
‘Dosing head’
2 -
‘Volume unit’
3 -
‘Pressure unit’
11.2.6.1
‘Dosing head ’
‘Menu / Information
è
Settings
è
System
è
Dosing head
è
...’
CAUTION!
Should a different liquid end size be fitted, then the
pump must be reprogrammed in the
‘Dosing head’
sub-
menu.
Reprogram the pump to
‘No dosing head’
for demon‐
stration purposes or if operating without feed chemical.
If ‘SEK’ has been selected as the type of head, the pressure
is not displayed and the ‘Automatic’ menu is hidden. Only
‘fast’ can be selected for the ‘Discharge stroke’ and
‘normal’ for the ‘Suction stroke’ .
11.2.6.2 Volume unit
‘Menu / Information
è
Settings
è
System
è
Volume unit
è
...’
You can select another unit for the volume in the
‘Volume unit’
sub-menu.
Set Up /
‘Menu’
56

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%