11.3.2
‘Password ’
‘Menu / Information
è
Service
è
Password
è
...’
You can enter a password of your choice in the
‘Change password’
menu.
11.3.3
‘Clear Counter’
‘Menu / Information
è
Timer
è
Clear counter
è
...’
You can reset the counter to "0" in the
‘Clear counter’
menu:
n
‘Stroke counter’
(total number of strokes)
n
‘Volume counter’
(total litres)
n
‘Contact memory’
n
‘All’
To clear: exit the menu by briefly pressing the
[Clickwheel]
.
The values have increased since commissioning of the pump, the last cali‐
bration or the last deletion.
11.3.4
‘Diaphragm Replacement’
‘Menu / Information
è
Service
è
Diaphragm replacement
è
...’
You can move the slide rod into the "replacement position" here with
‘To
replacement position’
to enable the diaphragm to be replaced more easily.
11.3.5
‘Display’
‘Menu / Information
è
Service
è
Display
è
...’
You can set the
‘Contrast’
and the
‘Brightness’
of the LCD screen here.
11.3.6
‘Reset to Factory Settings’
‘Menu / Information
è
Service
è
Reset to factory settings
è
...’
You can reset the pump to its factory settings here with
‘Yes’
11.4
‘Language’
‘Menu / Information
è
Language
è
...’
In the
‘Language’
menu, you can select the desired operating language.
Set Up /
‘Menu’
63

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%