List of directly changeable variables:
n Capacity
n Stroke rate
n Stroke length
n Factor
n Contact volume
n Batch dosing time
n Concentration
STOPSTOP
STARTSTART
1
Setting
mode
Continuous
display
Stop/start pump
Priming
Start batch (only in "Batch" operating mode)
Acknowledging errors
Check adjustable values
2
Changing directly changeable variables
B0598
Fig. 36: Control options using keys and locking options
Press
[Clickwheel]
Turn
[Clickwheel]
"Lock menu"
"Lock all"
Set Up Overview of the gamma/ X
Operation
65

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%