EasyManua.ls Logo

PVA JDX - Install Nozzle Plate and Feed Tube; Figure 4: Feed Tube and Nozzle Plate; Figure 5: Align the Heater Block and Nozzle Plate; Figure 6: Nozzle Plate

PVA JDX
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JDX
PVA
Revision H (2016)
10 of 39
Install Nozzle Plate and Feed Tube 3.2
1. Align the feed tube with the barb inlet on the nozzle plate.
2. Push the feed tube onto the barb inlet.
Figure 4: Feed Tube and Nozzle Plate
3. Align the nozzle plate on the heater block with the barb inlet facing toward the
syringe bracket. The heater block has two locating pins that will guide the
nozzle plate onto the heater block.
Figure 5: Align the Heater Block and Nozzle Plate
4. Make sure the nozzle plate faces the correct way.
Figure 6: Nozzle Plate