Communication Protocol CubiScan 125 Command Set
CubiScan 125 Service Manual 65
Factor Toggle
This command is used to set the dimensional factor to either domestic or international.
2 1 Dim. Unit Command Alpha (") 22h
3 1 Acknowledge Alpha (A) 41h
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Dim. Unit Command Alpha (") 22h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Fact. Toggle Command Alpha (F) 46h
3 1 Dom. / Int'l Alpha (D/I) 44h or 49h
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Fact. Toggle Command Alpha (F) 46h
3 1 Acknowledge Alpha (A) 41h
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Fact. Toggle Command Alpha (F) 46h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
Pos Len Description Type Range ASCII