Communication Protocol CubiScan 125 Command Set
CubiScan 125 Service Manual 75
Weight Units
This command is used to set the weight units to either English (pounds) or metric (kilograms)
mode.
Zero
This command should be issued periodically to force the CubiScan 125 to perform internal
compensations to adjust to changes in temperature and humidity. This command should only be
issued when the measuring field is free of packages! Never issue this command when a package is
present in the measuring field.
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Wgt. Unit Command Alpha (#) 23h
3 1 English or Metric Alpha (E/M) 45h or 4Dh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Wgt. Unit Command Alpha (#) 23h
3 1 Acknowledge Alpha (A) 41h
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Wgt. Unit Command Alpha (#) 23h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
21Zero Command Alpha (Z) 5Ah
31End of Text Control(ETX) 03h

Table of Contents

Other manuals for Quantronix CubiScan 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantronix CubiScan 125 and is the answer not in the manual?

Quantronix CubiScan 125 Specifications

General IconGeneral
BrandQuantronix
ModelCubiScan 125
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals