Communication Protocol CubiScan 25 Command Set
CubiScan 25 Service Manual 55
Build Number
This command causes the CubiScan 25 to report the build number. This is a non-lft function.
“Units” U 55h 73
“Values” V 56h 74
“Values 2” v 76h 76
“Weight Units” # 23h 77
“Zero” Z 5Ah 78
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Build Command Alpha (b) 62h
31End of Text Control(ETX) 03h
4 1 Carriage Return Control (CR) 0Dh
51Line Feed Control(LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Build Command Alpha (b) 62h
3 1 Acknowledge Alpha (A) 41h
4 2 Build Number Numeric 00-99
61End of Text Control(ETX) 03h
7 1 Carriage Return Control (CR) 0Dh
81Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Build Command Alpha (b) 62h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah

Table of Contents