R&S XU 4200 Local Control (Local Mode)
6166.5368.02.01 3.68
Setting the S/N squelch threshold
Meaning
of entries
S / N S Q
T
H
R
L
O
C
1
6
d B
Fig. 3.62 S/N squelch threshold.
Display text Description
S/N SQ THR Value for the S/N squelch threshold can be changed from 6 dB to 20 dB in
1 dB steps. Local mode is needed to set the value. If value is not set within
the range after pressing the ENTER key, a pop-up window indicating an
error appears (see the RSSI squelch threshold above).
Note: The thresholds are defined for S/N. The corresponding value of
SINAD will be 2 dB higher (SINAD 12 dB value corresponds with S/N 10 dB
value).
3.4.7.7.5 TX MODULATION DEPTH Menu
TX MODULATION DEPTH Menu\TX MODULATION DEPTH Menu "Radio ".doc
Meaning
of entries
T X
M
o
d
u
l
a
t
i
o
n
D
e
p
t
T X
M
O
D
D
e
p
t h
3
0
%
Fig. 3.63 TX MODULATION DEPTH Menu.
Display text Values Description
TX Modulation Dept – Menu name
Note: In the “TX Modulation Depth” submenu name an „h“ is
missing because the last three columns are reserved for status
indication (LOC).
TX MOD Depth 30 % Submenu for setting the modulation depth