Troubleshooting R&S XU 4200
4.15 6166.5368.02.01
Code Message Level Config Note Action
0351 TX PART a b c W Information about
booted TX FW and
device FW validity.
a = currently booted
partition, i.e. ‘1’ or ‘2’,
b = version number,
e.g. ‘10.xx’,
c = comparison result
defined as a bit-wise
mask (little endian),
where:
bit 0 set – comparison
fail, currently booted
partition numbers not
equal,
bit 1 set – comparison
fail, part numbers not
equal,
bit 2 set – comparison
fail, version numbers
not equal.
E.g. ‘0’ for case of
comparison passed or
‘6’ for case when
currently booted
partition numbers are
equal on MMI, TX and
RX, but part numbers
and version numbers
are not equal on at
least two modules.
This event is for
information only (see
chapter 4.2.3).
0352 TX RST REQ RC W After RC client sends
an RST command to
TX module, but before
reboot.
This event is for
information only (see
chapter 4.2.3).