Troubleshooting R&S XU 4200
4.19 6166.5368.02.01
Code Message Level Config Note Action
0407 RX IF OVERLOAD W Input RF signal is too
strongor RF AGC
failure occurred.
Receive signal too
strong.
Check the antenna signal
(see chapter 3.4.7.4.2);
there may be
strong
signals in the
VHF range.
Disconnect the antenna
from the receiver and
check the signal level of
the antenna signal.
If the antenna signal is
less than +10 dBm, send
the radio to service.
0408 RX DSP ERROR E Error in DSP. Send the radio to service.
0409 RX WD RESTART W Indication of restart
after the watchdog
timer expires.
This may be a software
error. Please report it to
the service. Restart and
observe.
If this fails to eliminate
the fault, send the radio
to service.
0410 RX SYNTH UNLOCK E Synthesizer unlocks. Send the radio to service.
0411 RX TEMP WARNING W Temperature on the RX
module is over the
warning limit (75 °C).
Check airflow of fans and
ambient temperature
(see chapter 5.2).
Clear the ventilation
opening.
If this fails to eliminate
the fault, send radio to
service.
0412 RX TEMP ERROR E Temperature on the RX
module is over the error
limit (85 °C).
Send the radio to service.
0414 RX USB CONNECT W W If this warning was
configured via the
service PC (see
chapter 3.3), you will
get a warning
message
when the USB is
c
onnected.