Interface Description  R&S XU 4200 
 6.5 6166.5368.02.01 
Entry in column D (direction): O =  Output  I =  Input    B = Bi-directional 
Entry in column T (type):  A = Analog  D = Digital  P = Power
 
Signal description  D T  Range  Contact  Remarks 
*OFF  I  D  Low (external contact 
against ground)  
= device off 
High (or open) = on 
Internal pull-up 10 k to 
3.3 V, limited to max. 
6.8 V 
X5.7  Hardware input for  
activating/deactivating 
transceiver  
module 
+PTT   I  D  X5.8 
–PTT I D 
Configurable via  
software 
X5.9 
Pull-up resistors  
connected via relay  
contact to internal supply 
+28 V/ –48 V 
Note: The PTT contact of 
the radio is low if the radio 
is switched off. 
Note: It is not 
recommended to switch 
the PTT Type during the 
operation. Make sure the 
hardware configuration is 
set according to the setup 
of the radio. 
  Type I: 
Optocoupler inputs 
+PTT and –PTT 
V = 12 V to 57 V 
I 
source = 2 to 13 mA 
  Type II: 
+PTT, pull-up –48 V 
Contact against 
GND = PTT 
I 
sink = –4 to –5 mA 
  R&S standard: 
–PTT, pull-up +28 V, 
contact against 
GND = PTT 
I 
sink = 3 to 4 mA