6 Replace left grid shelf to secure the descaler
hose.
7 Screw the hose to the canister of descaling
fluid.
8 Place the canister in the cabinet.
9 Guide the hose into the steam inlet up to the
mark shown on the hose. Fasten the hose to
the left grid shelf with the wire hook.
10 Use the appliance manufacturer’s hand pump
to very slowly fill with the amount of desca-
ling fluid shown on the display.
Caution!
• Descaling fluid reacts with lime and can
foam over.
11
As soon as the indicated amount of descaler
has been filled, please confirm input.
12 Remove the descaling accessories (hand
pump and canister) from the cabinet.
13 Rinse cabinet and descaling accessories
thoroughly with hand shower.
14 Insert air baffle and left grid shelf correctly
into the cabinet and lock properly.
15 Close the cooking cabinet door – Descaling
process starts automatically.
Descaling processes and descaling time are
shown on the display.
∆
∇
1:30
cooking cabinet
being rinsed
close door
stop filling?
fill 5 liter descaler
- 54 -
Service – Steam generator descaling