Descaling
Caution!
• The process described involves working
with an aggressive chemical fluid – danger
of corrosive burns!
• To prevent damage to materials and
health it is vital that you use:
protective clothing
safety goggles
protective gloves
face mask
the manufacturer’s descaler hand pump
• Thoroughly rinse descaling fluid spills with
water immediately.
• Thoroughly rinse descaler hand pump and
hoses with water after descaling.
You will need: descaler hand pump -
Part number: 60.70.409
Descaler
(10 litre canister Part number 6006. 0110)
1
2
3
Follow user prompt
Note:
If the cabinet temperature exceeds 40 °C,
the display will show the message:
4
Please cool the cabinet with "Cool down".
Once your unit has cooled down you can continue
descaling
Wait until the steam generator has cooled down.
5 Remove left grid shelf and air baffle.
∆
∇
3:00
wait cool
steam generator
close door
descale
open door
unit to hot
- 53 -
Service – Steam generator descaling