Descaling
Caution!
The process described involves working
with an aggressive chemical fluid danger
of corrosive burns!
To prevent damage to materials and
health it is vital that you use:
protective clothing
safety goggles
protective gloves
face mask
the manufacturers descaler hand pump
Thoroughly rinse descaling fluid spills with
water immediately.
Thoroughly rinse descaler hand pump and
hoses with water after descaling.
You will need: descaler hand pump -
Part number: 60.70.409
Descaler
(10 litre canister Part number 6006. 0110)
1
2
3
Follow user prompt
Note:
If the cabinet temperature exceeds 40 °C,
the display will show the message:
4
Please cool the cabinet with "Cool down".
Once your unit has cooled down you can continue
descaling
Wait until the steam generator has cooled down.
5 Remove left grid shelf and air baffle.
3:00
wait cool
steam generator
close door
descale
open door
unit to hot