Efficient CareControl
98 / 203
Warning!
- Do not open the cooking chamber door while cleaning is in progress – chemical cleaner
and hot vapour may escape – risk of chemical burns and scalding. A horn sound is heard
if the door is opened during the cleaning process.
-
Once the CleanJet
®
+care cleaning process is aborted or has ended, check the entire
cooking chamber (also behind the air baffle) for any cleaning tab residues. Thoroughly
rinse away any cleaning tab residues from the entire cooking chamber (also behind the
air baffle) with the hand shower - risk of chemical burns.
- During cleaning, all external core temperature probes may not be inserted through the
cooking chamber door in the cooking chamber. These sensors must not be cleaned with
the chamber! This leads to leaks during cleaning.Danger of chemical burns and scalding!
Chemical handling instructions
Warning!
Only use cleaning and care
tabs by complying with the
relevant safety measures,
always wear, for example,
protective gloves when
handling the tabs - risk of
chemical burns!
Table-top appliances:
Fill the tray with the
displayed quantity of care
tab packages.
Standalone appliances:
Fill the flap with the
displayed quantity of care
tab packages.
Cleaning tab: Remove
protective film.
Insert the cleaning tabs into
the indentation in the air
baffle.
Do not insert tabs into the
cooking chamber - risk of
damage.