Operation QUANTRON-A 4
60
MAN scale: manual operation with scale value
1. Open the Machine settings > AUTO/MAN mode menu.
2. Select MAN scale in the menu.
The display shows the metering slide opening menu.
3. Enter the scale value for the metering slider opening.
4. Press the Enter key.
See 4.13.2: Entering values with the cursor keys, page 84
.
The operating mode setting is saved.
The MAN scale operating mode enables manual adjustment of the metering slide
opening during the spreading operation.
Precondition:
The metering slides are open (activation with the Start/Stop key).
In the MAN scale operating screen, the icons for sections are filled in red.
Figure 4.18: MAN scale operating screen
[1] Display of current metering slider scale position
5. For changing the metering slide opening press F2 or F3.
F2: MAN+ to increase the metering slide opening
F3: MAN- to reduce the metering slide opening.
NOTICE
In order to achieve an optimum spreading result even in manual mode, we rec-
ommend using the values for metering slide opening and forward speed provid-
ed in the fertiliser chart.
1