4
Manual No. 016-0230-004 Rev. F 31
PowerGlide Plus
FIGURE 3. Coil Removed from the AutoBoom Valve
2. Remove the coils from the solenoids near Ports 3A and 3B to gain easy access to those ports.
FIGURE 4. Port Plugs Removed from the AutoBoom Valve
3. Use an Allen wrench to remove the plugs from Ports 3A and 3B.
FIGURE 5. Orifice Fitting Removed from the AutoBoom Valve
4. Remove the orifice fittings from Ports 3A and 3B.
Orifice Fitting
Removed - Keep for
Future Use