4
Manual No. 016-0230-004 Rev. F 37
PowerGlide Plus
FIGURE 13. Left and Right Cylinder Hoses Connected to the AutoBoom Valve
6. Connect the 90° end of the installed hydraulic hose to the fittings installed in Port LC of the AutoBoom
valve.
7. Disconnect the machine’s hose from the right tilt cylinder.
8. Install a 13/16” ORFS M/M/F swivel run tee adapter fitting (P/N 333-0012-028) on the right tilt cylinder.
9. Reinstall the machine’s hose on the opposite end of the installed tee fitting.
10. Install a 13/16” ORFS M/F 90° swivel elbow fitting (P/N 333-0012-067) on the 90° end of the installed tee
fitting.
11. Install the 90° end of the supplied hydraulic hose (P/N 214-1000-300) on the 90° end of the installed tee
fitting.
12. Connect the straight end of the installed hydraulic hose to Port RC of the AutoBoom valve.