62 Miller Nitro 2000 Series AutoBoom™ Installation Manual
6. Install a 13/16” ORFS M/M/F swivel run tee adapter fitting (P/N 333-0012-028) on the adapter fitting
installed on the ball valve.
7. Reinstall the machine’s hose on the opposite end of the tee fitting.
8. Connect the straight end of the supplied hydraulic hose (P/N 214-1000-299) to the installed tee fitting.
9. Connect the 90° end of the installed hydraulic hose to the installed fitting in Port LC of the AutoBoom valve.
10. Disconnect the machine’s hose from the right accumulator.
11. Install a 13/16” ORFS (F) to 11/16” ORFS (M) reducer (P/N 333-0012-115) on the accumulator.
12. Connect a 9/16” SAE O-ring (M) to 11/16” ORFS swivel straight adapter fitting (P/N 333-0012-081) to the
9/16” SAE O-ring (F) to 9/16” SAE O-ring (F) ball valve (P/N 334-0003-036).
13. Connect the ball valve and fitting assembly to the installed reducer fitting.
14. Connect the 13/16” ORFS (M) to 9/16” SAE O-ring (M) straight adapter fitting (P/N 333-0012-082) to the
installed ball valve.
15. Install a 13/16” ORFS M/M/F swivel run tee adapter fitting (P/N 333-0012-028) on the adapter fitting
installed on the ball valve.
16. Reinstall the machine’s hose on the opposite end of the tee fitting.
17. Connect the straight end of the supplied hydraulic hose (P/N 214-1000-300) to the installed tee fitting.
18. Connect the 90° end of the installed hydraulic hose to the installed fitting in Port RC of the AutoBoom valve.