CONNECTION DIAGRAM FOR THE PRIMULA-ORCHIDEA HYDRO STOVE EQUIPPED WITH KIT FOR
DOMESTIC HOT WATER PRODUCTION
5
7
46 55 55
71
178
4
0
9
5
A1
C
B1 A2
B2
E
CONNECTION DIAGRAM FOR GARDENIA-MARGHERITA HYDRO
STOVE
A1=Heating water delivery 3/4”M
A2=Heating water return 3/4”M
C=Safety valve 3/4”M
E=System emptying 3/4”M
A1= Heating water flow pipe 3/4”M
A2= Heating water return pipe 3/4”M
C= 3 bar safety shut off valve– 1/2”F
E= System emptying device 1/2”F
B1= Domestic water flow pipe
B2= Domestic water return pipe