PELLET STOVES Chapter 4
red
INSTALLATION AND USE MANUAL
page 51
Operation Technical service - Rights reserved - Reproduction prohibited
set
+ 3
To confirm the selection you have made, you must
press the button
until the display once again
shows the time and the message “OFF”.
The default recipe for the stove is 0, for all versions
and for all countries.
4.11. SAFETY DEVICES
The stove is fitted with the following safety devices:
PRESSURE SWITCH
Monitors pressure in the smoke duct. It is designed to shut down
the pellet feed screw in the event of an obstructed flue or
significant back-pressure (from the wind).
SMOKE TEMPERATURE SENSOR
Monitors the temperature of the smoke, and gives permission for
startup or shuts the stove down when the smoke temperature falls
below the preset value.
CONTACT THERMOSTAT IN THE FUEL HOPPER (KLIXON)
If the temperature exceeds the preset safety level, it immediately
shuts down the running of the stove.
CONTACT THERMOSTAT IN THE BOILER
If the temperature exceeds the preset safety value, it immediately
shuts down stove operation.
WATER TEMPERATURE PROBE
If the temperature of the water approached shutdown temperature
(85°C), the probe causes the stove to go through a series of
cooling cycles or “ECO-STOP” automatic shutdown to prevent
blocking of the bulb temperature probe as described above.
ELECTRICAL SAFETY
The stove is protected against violent surges of current by the
main fuse, which is located on the control panel at the rear of the
stove. Other fuses to protect the electronic boards (main board
and heat-exchanger board) are to be found on the boards
themselves.
SMOKE FAN
If the fan stops, the electronic board shuts off the supply of pellets
in good time, and an alarm message is displayed.
REDUCTION MOTOR
If the reduction motor stops, the stove will continue to run until
the flame goes out due to lack of fuel and until a minimum level of
cooling is reached.
TEMPORARY POWER OUTAGE
After a brief power outage, it automatically goes into cooling
mode.
FAILURE TO LIGHT
If during ignition no flame develops, the stove will go into alarm
condition.