PELLET STOVES Chapter 4
red
INSTALLATION AND USE MANUAL
page 53
Operation Technical service - Rights reserved - Reproduction prohibited
SET
TURBO
1
2
64
3
5
!
ALAR
4.11.1. Alarm signalling
If an operating anomaly occurs, the stove is equipped with a
computerized monitoring system that informs the user via the display
(8) of the nature of the problem and where it has occurred.
The following table summarises the principal alarms which may be
indicated
Message on the
display (8)
Type of problem Solution
ALAR DEP FAIL Obstruction of smoke dischar
e duct or ne
ative pressure
caused by wind.
Check and clean the ENTIRE smoke duct, or check tha
t
the wind outdoors is not preventin
g
the release o
f
smoke. Install a wind cowl.
Only after the cause of the blocka
g
e has been
permanently eliminated can another attempt to reli
g
h
t
the stove be made.
ALAR FAN FAIL Fan speed too low or fan off
The smoke fan is blocked.
Check for cleanliness and whether the is slowin
g
the fan.
If cleanin
g
does not solve the problem, repalce the
smoke fan
ALAR SMOKE PROBE Smoke sensor short circuit Replace smoke sensor
ALAR SIC FAIL
T
he pellet tank temperature safety device has been
triggered.
A system failure has caused the water to overheat.
Check the parameters of the recipe used
Check the hydraulic system
ALAR HOT TEMP This occurs when the smoke temperature exceeds 180°
for an excessive length of time.
Clean the inside of the heat exchan
g
er and run the stove
at full power for shorter periods of time. Also check the
quality of the pellets.
ALAR NO ACC Occurs on first failed attempt at lighting If this is the first attempt at li
g
htin
g
, reli
g
ht or check the
level of pellets in the hopper.
Check the ignition plug.
ALAR NO FIRE Occurs when the stove
g
oes out and when the
temperature of the smoke sensor is below the preset
threshold.
It is caused when the flame is extin
g
uished due to
clo
gg
in
g
or when there are no lon
g
er any pellets in the
hopper.