PELLET STOVES Chapter 5
red
INSTALLATION AND USE MANUAL
page 59
Maintenance and cleaning Technical service - Rights reserved - Reproduction prohibited
ATTENTION:
The frequency with which the smoke discharge
system is cleaned should be determined based on the
type of use that is made of the stove and the type of
installation.
We recommend relying on an authorized service
centre for end-of-season cleaning and maintenance,
they will carry out all of the previously mentioned
work and make a general check of the stove's
components.
5.2.2. Shutting the stove down (end of season)
At the end of season, before shutting down the stove, we recommend
completely removing pellets from the hopper with the use of a vacuum
cleaner with an extension.
During periods of disuse, the stove must be unplugged and
placed in a dry place protected from the elements. For greater
safety, especially if there are children around, we recommend
removing the supply cable from the rear of the stove.
Upon re-start, when pressing the main switch (located on the back of
the stove) does not make the control panel display light up, it could
mean that the service fuse needs replacing.
On the rear of the stove there is a fuse holding compartment which is
located underneath the supply socket. Use a screwdriver to open the
fuse-holder compartment and if necessary replace them (3.15 AT
delayed)
5.2.3. Check of internal components
ATTENTION!
The check of the internal electro-mechanical
components must be carried out only by qualified
personnel with technical knowledge of electricity and
combustion.
We recommend that an annual maintenance service is carried out,
preferably under a programmed service contract. The essential part of
this service is a visual and functional check on the following
components:
Reduction motor
Smoke expulsion fan
Smoke sensor
Heat-exchanger fan
Ignition sparkplug
Automatic resettable pellet/water thermostat
Room/water probe
Motherboard
Fuses protecting panel - motherboard
Wiring