PELLET STOVES Chapter 4
red
INSTALLATION AND USE MANUAL
page 37
Operation Technical service - Rights reserved - Reproduction prohibited
SET
TURBO
1
2
64
3
5
!
16
:
Ut 0 2
SET
TURBO
1
2
64
3
5
!
:
10
Ut 0 3
4.5. SETTINGS TO CARRY OUT BEFORE FIRST
LIGHTING
Set the main switch on the rear of the stove to position (I).
The display (8) of the control panel will show the message OFF and the
CURRENT TIME.
If the time shown is not correct, it can be reset by the procedure
described below.
You should keep in mind that the current time is only
needed when you carry out weekly programming
using the TIMER (see corresponding chapter). If the
time is not set correctly, this does not in any way
affect stove operation.
4.5.1. SETTING CURRENT TIME
In rapid sequence, press the buttons and to access technical
parameter
UT01
. If you again press the button , you will access item
UT02, which shows the hours. Use the buttons
or to decrease or
increase the hours.
To confirm the hour selected and move on to selection of the minute,
press key
. (you will see the item
UT03
)
Use keys
or to decrease/increase the minute (steps of 1 minute).
To confirm the set time and exit, press
4.6. CONTROL OF WATER TEMPERATURE IN
BOILER
The stove is already set with a series of standard parameters that allow
it to operate properly (water temperature 65°C and ambient
temperature 22°C). However, the user can change these parameters in
the following way:
The following parameters can be set:
T Ambient This is the temperature that you want to attain in the
room where the stove is installed. To adjust it, press
ONCE on the button
“SET” and change the
values using the buttons
or
T H
2
O = Maximum temperature of water in boiler. Upon reaching
this temperature, the stove will reduce its performance to
prevent overheating. The default temperature is 65°C
and it can not be set below 40°C or over 80°C.
To adjust it, press TWICE in rapid succession on the
button
“SET” and change the values using the
buttons
or
It is not advisable to set the temperature below
50/55°C so as to prevent the formation of
condensation in the boiler
SET
TURBO
1
2
64
3
5
!
day 1
Ut 01
System pressure temperature setting
Setting of ambient temperature
SET
TURBO
1
2
64
3
5
!
AMB
22°C
SET
TURBO
1
2
64
3
5
!
H2O
70°C