SYSTEM DELIVERY
SYSTEM RETURN
COLD DOMESTIC
WATER INLET
HOT DOMESTIC WATER OUTLET
PRESSURE SAFETY
DISCARGE
SYSTEM REFILL
3.6.2. Installation diagram for heating system with domestic hot water kit
(PRIMULA/ORCHIDEA)
230V 50HZ
SE
S
T
VS
P
VE
V
V
VD
VD
V
T
SC
VV
R
HEATING WITH STOVE
RA RA RA RA
Vsc
Flt
Add
A
RP
V
V
V
M
PRODUCTION OF DOMESTIC HOT WATER WITH STOVE
SISTEMY DELIVERY
SYSTEM RETURN
COLD DOMESTIC WATER INLET
HOT DOMESTIC WATER OUTLET
SYSTEM REFILL
PRESSURE SAFETY DISCHARGE
PERFORMANCE:
CONFIGURATION: PRIMULA/ORCHIDEA WITH DOMESTIC HOT WATER KIT
SYSTEM OF DIAGRAM WITH CLOSED TANK FOR HEATING WITH RADIATORS OR FOR THE PRODUCTION OF DOMESTIC HOT WATER
SIGNATURFORKLARING:
SE Electronic card
S Automatic vent
M Pressure gauge
VS Vent valve, 3 bar
V Valve
P Pump
VD One-way valve
T Measurement of boiler temperature
VE Expansion tank, 1.5 bar of 6 l
W 3-way motorized valve
SC Plate heat exchanger
F Flow switch
C Methane gas boiler
B Boiler
BA Storage boiler
RA Radiators
PR Radiant panels
PS Solar panels
A Pounding absorber
RP Pressure reduction valve
Vsc Boiler/system discharge valve
Flt System filter
Add Softener
3.6.3. Heating installation diagram in combination with a boiler
PERFORMANCE:
HEATING WITH STOVE
PRODUCTION OF DOMESTIC
HOT WATER WITH BOILER
CONFIGURATION: PRIMULA/ORCHIDEA – GARDENIA/MARGHERITA WITHOUT DOMESTIC HOT WATER KIT COMBINED WITH BOILER
HEATING WITH STORAGE SYSTEM PRODUCTION OF DOMESTIC HOT WATER WITH STORAGE SYSTEM
SIGNATURFORKLARING:
SE Electronic card
S Automatic vent
M Pressure gauge
VS Vent valve, 3 bar
V Valve
VD One-way valve
T Measurement of boiler temperature
VE Expansion tank, 1.5 bar of 6 l
W 3-way motorized valve
SC Plate heat exchanger
C Methane gas boiler
B Boiler
BA Storage boiler
RA Radiators
PR Radiant panels
A Pounding absorber
RP Pressure reduction valve
Vsc Boiler/system discharge valve
Flt System filter
Add Softener