PELLET STOVES Chapter 6
red
INSTALLATION AND USE MANUAL
page 63
Problems / Causes / Solutions Technical service - Rights reserved - Reproduction prohibited
ANOMALIES RELATED TO THE PLUMBING CIRCUIT
PROBLEM POSSIBLE CAUSES REMEDY
No increase in
temperature with
stove in operation
1. Incorrect combustion adjustment.
2. Boiler / system dirty.
3. Insufficient stove power.
4. Poor pellet quality
1. Check recipe and parameters.
2. Check and clean the boiler.
3. Check that the stove is properly sized
for the requirements of the system.
4. Use quality pellets.
Condensation in
boiler
1. Incorrect temperature setting.
2. Insufficient fuel consumption.
1. Set the stove to a higher
temperature.
2. Check the recipe and/or technical
parameters.
Radiators cold 1. Room thermostat (local or remote)
set too low. If remote thermostat,
check if it is defective.
2. Circulator does not run because
blocked.
3. Circulator does not run.
4. Radiators have air in them
1. Set to higher temperature or
replace. (if remote)
2. Free up the circulator by removing
the plug and turning the shaft with a
screwdriver.
3. Check the electrical connections of
the circulator; replace if necessary.
4. Vent the radiators
High variability of
temperature of
domestic hot water
1. Water flow rate too low.
1.
Increase the water flow rate
(minimum 3 litres per minute)
Little domestic hot
water is provided
1. Insufficient mains pressure
2. Tap or mixer clogged with limescale
3. Water group clogged
1.
Check the calibration of the
pressure reducer.
2.
Install and autoclave
3.
Check and clean
4.
Clean or replace the plate heat
exchanger
Hot water is not
provided
1. Circulator (pump) blocked
1.
Free the circulator (pump)
ATTENTION!
The operations
in italics
must be carried out by
specialised personnel.
The manufacturer refuses to accept any responsibility
and the guarantee lapses if this condition is not
respected.

Table of Contents